Adjustpressure of the blasting system per Owners Manual
Turn upthe media rate to the next highest number
Checkfor media clogs, cuts in tube and kinks
Changethe type of media to a more aggressive media
PUMP LEAKS WATER
CAUSE:
Thermal release valve leaks water
Pump seals or valves are worn
SOLUTION:
The water temperature inside the pump has exceeded the set limit; squeeze the trigger to allow cool water to flow thru the pump. Do not allow pressure blasting system to idle for extended periods.